Creative Communities of the World Forums

The peer to peer support community for media production professionals.

Activity Forums Broadcasting error code on PVW-2800

  • error code on PVW-2800

    Posted by Scott Tupper on March 16, 2009 at 9:37 pm

    Can somebody help me out in identifying error code 90 from a PVW-2800?
    My deck when poof this morning and this is all it told me before it let out that wonderful smell we all hate.

    I don’t have a manual otherwise I would try to find it myself.

    Thanks for the help!

    Scott Tupper replied 17 years, 1 month ago 2 Members · 2 Replies
  • 2 Replies
  • Steve Schroeder

    March 20, 2009 at 7:58 pm

    Error 90 is Key Interface Error. “The interface between the keyboard and system control is defective.” The manual points to a problem with the SS48 board or the key pad itself. Did the ribbon cable on the key pad get pinched?

  • Scott Tupper

    March 24, 2009 at 5:27 pm

    Nope just sitting in the rack. Funny thing it seems to be working again.